Ideal
for
tests on
telephone
lines or
electronic
equipment,
the C.A
6533
megohmmeter
measures
insulation
at 50V,
100V,
250V and
500V, as
well as
resistance.
It
indicates
the
AC/DC
voltage
before
each
measurement.
insulation:
up to
20GΩ at
50V,
100V,
250V and
500V
voltage
indication
before
insulation
measurement:
0 to
600V
AC/DC
(blocking
if
U>25V)
resistance:
0 to
400kΩ
giant
4,000-count
display
+
bargraph
(simultaneous
reading
of the
measurement
and
analogue
variation)
backlit
display
programmable
alarms
DREL
function
for
testing
for the
presence
of
transmission
frame or
measurement
of the
difference
in
resistance
between
2 wires
of a
pair
remote
control
probe
(option)
back
stand
for use
on a
table or
on the
ground
long
battery
life: 6
x 1.5V
batteries
Measurements
in
compliance
with IEC
61557,
NF C
15-100,
VDE 0413
electrical
safety:
IEC 1010
300V
Cat. III
|
|
 |
Name:
Professional Plant Digital
Multimeters
Spec:
Voltage Measurement ACV - 999.9mV;
9.999, 99.99, 750.0V; DCV - 999.9mV;
9.999, 99.99, 999.9V Amperage
Measurement ACA - 400.0?A; 40.00mA;
10.0A; DCA - 40.00, 400.0?A; 4.000,
40.00mA; 4.000, 10.00A Resistance
999.9GO; 9.999, 99.99, 999.9kO;
4.000, 40.00MO Capacitance 1.000,
10.00, 100.0?F; 1.000, 10.00mF
Frequency 9.999, 99.99, 999.9Hz;
9.999, 50.00kHz Temperature K type,
-4?F to 932?F (-20?C to 500?C)
Measurement Category Cat III, 600V;
Cat II, 750V AC/1000V DC per UL
3111-1
Description:
DM-500 features:
Autoranging for convenient operation
and to save you time.
Record max, min, max-min, and
average readings and data hold.
Relative offset display mode to see
relative changes in measurements.
Frequency, temperature, and
capacitance measurements plus diode
and continuity tests standard.
Auto power off and low battery
indicator.
DM-510 also features:
HAR feature to measure harmonic
content.
True RMS for no-compromise accuracy.
Accessories included: (1) 9V
battery, test leads, bead
temperature probe.
|
|  |
DM-800 features:
• Autoranging, 3-5/6-digit, 5000-count display for greater accuracy.
• Frequency and capacitance measurements plus diode and continuity
tests standard.
• Data hold to capture measurements.
• RS-232 capable, may be connected to a PC for extended measurement
capability with optional optically isolated interface DMSC-8L or
DMSC-9, purchased separately.
• Low ohm range calibration, subtracts test lead resistance.
• Backlit display for easy viewing.
DM-810 also features:
• True RMS for no-compromise accuracy.
DM-820 also features:
• Record max, min and max-min readings.
• Crest capture (5ms peak hold) max, min and max-min readings.
• Relative offset display mode to see relative changes in measurements.
• Temperature measurement standard.
Accessories included: (1) 9V battery, protective boot, carrying case
(DM-820, DM-810), bead temperature probe (DM-820 only,
400ºF/204ºC max), test leads.
• Lifetime Limited Warranty.
|
| 
|
Description:
Auto and manual ranging
Non-contact and single-probe voltage detection
Beep-Jack™ audible and visible warning to guard against
improper A and mA terminal plug in.
High visibility 6000 count LCD display.
Auto power off, display backlight, analog bar graph
PC interface capability using optional USB RS-232 cable
with data recording PC software.
Lifetime Limited Warranty.
Spec:
Voltage Measurement: 60mV to 1000V AC/DC
Amperage Measurement: 600mA to 8A AC/DC
Resistance: 600Ω to 60MΩ
Frequency (Hz): 50 ~ 400
Measurement Category: Cat IV, 300V; Cat III 600V, Cat
II 1000V
|
|
Part Number |
Description |
Price/Unit (RM) |
|
ERO160 |
CABLE
END CAP |
|
| 
|
Suitable for Power
Cables, Telecom Cables, Jelly Filled Cables & Optic
Fibre Cable Compatible with most commonly used Cable
Jackets i.e. XLPE, PVC, PILC or Rubber Sheathed.
Quick
& foolproof installation using simple tools.
A
strong & permanent environmental seal.
Excellent
resistance to weathering, moisture contamination &
adverse environmental conditions.
Special
adhesive lining provides seal on irregular cable
sheaths.
Valved
end Cap available for pressurized application.
|
|
Part Number |
Description |
Price/Unit (RM) |
|
DM2500a |
2500A Industrial Clamp Meter |
|
|

|
• True RMS for accurate measurement when harmonics are
present.
• High capacity 2500A DC, 2100A AC amperage measurement.
• 600V AC/DC voltage, frequency, and resistance
measurements for maximum versatility.
• Peak hold, min-max, relative offset and analog bar
graph to help monitor power changes.
• Produces 1mV per amp output to allow use as a remote
transducer, linke to a multimeter or oscilloscope.
• Auto power off for longer battery life.
• Accessories included: (1) 9V battery, test leads,
carrying case.
• Lifetime Limited Warranty.
SPECIFICATIONS
Amperage Measurement AC – 400.0, 2100A; DC – 400.0,
2500A
Voltage Measurement AC – 4.000, 40.00, 400.0, 600V
DC – 400.0mV; 4.000, 40.00, 400.0, 600V
Display 3-3/4-digit, 4000-count (9999 for frequency)
Frequency 99.99, 999.9Hz; 9.999, 99.99, 999.9kHz
Resistance 400.0Ω; 4.000, 40.00, 400.0kΩ; 4.000, 40.00MΩ
Jaw Opening 2.17" (55 mm)
Voltage Output 1mV output per 1 amp input
Measurement Category CAT III, 600V
|
|
Part Number |
Description |
Price/Unit (RM) |
|
TG600 |
TG-600 Infrared Thermometer |
|
|
 |
• Safe,
non-contact temperature measurement.
• Laser indicates approximate center of the target area.
• Displays temperatures in either Fahrenheit or Celsius.
• Auto power off for longer battery life.
• Easy-to-read backlit display for use in low light
conditions.
• Accessories included: (1) 9V battery and carrying
case.
• Lifetime Limited Warranty
SPECIFICATIONS
Amperage Measurement AC – 400.0, 2100A; DC – 400.0,
2500A
Voltage Measurement AC – 4.000, 40.00, 400.0, 600V
DC – 400.0mV; 4.000, 40.00, 400.0, 600V
Display 3-3/4-digit, 4000-count (9999 for frequency)
Frequency 99.99, 999.9Hz; 9.999, 99.99, 999.9kHz
Resistance 400.0Ω; 4.000, 40.00, 400.0kΩ; 4.000, 40.00MΩ
Jaw Opening 2.17" (55 mm)
Voltage Output 1mV output per 1 amp input
Measurement Category CAT III, 600V
|
|